Why Powerflush?

Reasons to consider a Power flush

It is common at this time of year that people find problems with their central heating system due to the system having minimal use over the past several months. It is often slow to heat up, cold radiators, and many cold spots etc.


We can tell if your system is in need of a power flush by carrying out simple tests on the quality of the water contained within the circuit.  Following a power flush, the quality of the water should be equal to or as near as possible to the quality of the water coming into the property from mains.  


Bayden has undertaken training by Kamco and we use only Kamco power flushing equipment (clearflow CF90 Quantam machines).

Kamco is one of the leading suppliers in the UK of power flushing equipment.


Details of Chemicals used in Power Flushing


 Cleaning Chemicals:

  • Cleaning agent for central heating systems. Specially developed for use with power flushing equipment.
  • Removes iron and calcium-based deposits to restore circulation and system efficiency.

 Inhibitors

To give total protection against scale and corrosion. For use in all types of indirect central heating systems, including those containing aluminium. Non-acidic.

  • Ensures Optimum Boiler Efficiency
  • Prevents Pin-Holing
  • Non-Staining, Colourless Formulation

 Leak Sealers:  

Internal Leak Sealer for small inaccessible leaks and weeping joints.

  • Can be used in all types of indirect heating systems including those containing aluminium components.


 Power Flush Disclaimer

Central heating system power flushing – Disclaimer

Please read carefully

The core component of a heating system is the boiler. When a boiler is renewed, the boiler manufacturers’ Benchmark scheme requires that the system be thoroughly cleansed to the BS7593:2006 Code of Practice. Currently, best industry practice is considered to be to power flush the system.

Power flushing is the fastest and most effective way to flush heating systems, and involves minimal disruption and dismantling.

We use purpose built power flushing pumps, designed to cure the circulation and boiler noise problems caused by accumulations of sludge, corrosion deposits and scale which are found in most ageing central heating systems.

The power flushing pump is temporarily connected into a heating system during the flushing process. The high water velocity, combined with instantaneous flow reversal, dislodges and mobilises sludge and corrosion deposits.

Having loosened the debris, the pump expels it from the system to waste, using a high velocity flow of fresh water.

Radiators are individually flushed without removal or disconnection from the system. After the power flush, the system is full of clean water, and re-instatement to normal operation takes only a few minutes.

A power flush can be extremely effective in cleaning systems that have corrosion problems as a result of a design fault, but we strongly recommend that any such design faults be rectified before power flushing commences.

The success of a power flush will depend on the level of heating system corrosion which has occurred beforehand. The process will cure most circulation problems, but cannot undo the corrosion and gradual decay that has led to the need to power flush the system.

Whilst it is rare for a heating system to experience leaks after the power flushing process, it is not possible to inspect a system internally beforehand, and the need to use a flushing and dispersing chemical for effective cleansing means that occasionally we may find a leak

The advanced stage of corrosion required for such a situation means that the leak would occur imminently even without a power flush. We believe that it is better that it occurs whilst we are present to remedy the problem, rather than for it to arise over a weekend or whilst the house is unoccupied.

Systems which have been neglected over a period of time, or have not been treated with an effective corrosion inhibitor, may have severely compacted corrosion debris, in the pipe work, radiators, or boiler, and it is possible that even after the power flush, some radiators may still not be fully effective, or boilers on the margin of failure may cease working due to sludge and debris later breaking loose and collecting in the heat exchanger.

 

The price that we have stated allows for a standard power flush only and if any of the above or similar problems arise during or after the power flush we will not hold ourselves responsible in any way.

Any further work required would be carried out at an additional cost.

 



 

 